Interpreter
In IssueTracker #99, I made some incorrect comments on how the Interpreter treats coercion between elements of the two domains Variable(x:Symbol)
and Symbol
. This new page consists of experiments to find out more, in regard to both the Interpreter and the Compiler. Note that the domain constructor Variable(x:Symbol)
contains a unique element with output representation x
which may be coerced to the symbol x
. The domain Symbol
consists of all symbols (I know this does not say anything, but I won't dare to say it consists of all undeclared identifiers or all variables).
(1) -> )clear all
All user variables and function definitions have been cleared.
)set output tex off
)set output algebra on
)set mess bot on
Your user access level is compiler and this set option is therefore not available. See the )set userlevel command for more information. t:Boolean:= x = y
(1) false
Note when an undeclared identifier x
is used, the interpreter temporarily turns it into the only element of Variable(x:Symbol)
, see (1) where x
and y
are interpreted as of type Variable()
, not Symbol
. Unlike Symbol
, there is no equality testing across different Variable()
domains and so in (1) both x
and y
are coerced to Symbol
.
x:Variable(y):= y
(2) y
This is confirmed by (2), where the assignment is immediate because y:Variable(y)
. Thus from Symbol
to Variable()
seems to me automatic in the interpreter but temporarily. Temporarily, because you can reassign the identifier to any other typed value. This is different than manually declaring the identifier as y: Variable(y)
. You cannot reassign with y:=1
later without changing the declaration of its type.
However, I was not able to find any function that does this: y +->Variable(y)
and we know why: the target domain is dependent on the input.
t:= ((x::Symbol)=y)
(3) true
t:= (x = (y::Symbol))
(4) true
)set mess bot off
Your user access level is compiler and this set option is therefore not available. See the )set userlevel command for more information.
The absence of this map's signature may be why in (3), the Interpreter did not coerce x:Symbol
to x:Variable(y)
, but did the opposite. Same for (4), it coerces x:Variable(y)
to x:Symbol
.
The difference between y:Variable(y)
and y:Symbol
for the interpreter is thus that an undefined identifier y
behaves as Symbol
only transiently on its way to Variable(y)
, and need to be explicitly coerced back to Symbol
.
Compiler
Now, the real confusion is when one starts using the compiler! (By the way, in Windows 0.1.4 version, all compiling of the test packages, a message appears:
The syntax of the command is incorrect.
This does not appear below. Also there is a problem with MathAction/Wiki processing a comment line such as
--%SymbolVariableTest1
So these are omitted from below.)
(a) Without any prior declarations or assignments, you can compile within a routine, y: Variable(y):= y
(SVT1
below) but not x: Variable(y):= y
(SVT2
). Both are acceptable in the interpreter. So in the first case, the y
on the rhs is of type Variable(y)
, but not in the second case (SVT2
), where it is untyped and unassigned. According to Section 6.16 of the Axiom book, I think both y
on the rhs is free (global) the first time it is encountered in the subroutines.
)abbrev package SVT1 SymbolVariableTest1 SymbolVariableTest1(): Spec == Imp where Spec == with symVar1:() -> Boolean Imp == add symVar1()== y: Variable(y) := y x: Variable(y) := y t: Boolean := (x = y)
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/2836962772639158623-25px004.spad using old system compiler. SVT1 abbreviates package SymbolVariableTest1 ------------------------------------------------------------------------ initializing NRLIB SVT1 for SymbolVariableTest1 compiling into NRLIB SVT1 compiling exported symVar1 : () -> Boolean Time: 0 SEC.
(time taken in buildFunctor: 0)
;;; *** |SymbolVariableTest1| REDEFINED
;;; *** |SymbolVariableTest1| REDEFINED Time: 0 SEC.
Warnings: [1] symVar1: y has no value
Cumulative Statistics for Constructor SymbolVariableTest1 Time: 0 seconds
finalizing NRLIB SVT1 Processing SymbolVariableTest1 for Browser database: --->-->SymbolVariableTest1(constructor): Not documented!!!! --->-->SymbolVariableTest1((symVar1 ((Boolean)))): Not documented!!!! --->-->SymbolVariableTest1(): Missing Description ; compiling file "/var/aw/var/LatexWiki/SVT1.NRLIB/SVT1.lsp" (written 09 OCT 2024 08:13:22 PM):
; wrote /var/aw/var/LatexWiki/SVT1.NRLIB/SVT1.fasl ; compilation finished in 0:00:00.008 ------------------------------------------------------------------------ SymbolVariableTest1 is now explicitly exposed in frame initial SymbolVariableTest1 will be automatically loaded when needed from /var/aw/var/LatexWiki/SVT1.NRLIB/SVT1
symVar1()
(5) true
)abbrev package SVT2 SymbolVariableTest2 SymbolVariableTest2(): Spec == Imp where Spec == with symVar2:() -> Boolean Imp == add symVar2()== x: Variable(y):=y t:Boolean:= true
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/2427935065936506711-25px006.spad using old system compiler. SVT2 abbreviates package SymbolVariableTest2 ------------------------------------------------------------------------ initializing NRLIB SVT2 for SymbolVariableTest2 compiling into NRLIB SVT2 compiling exported symVar2 : () -> Boolean ****** comp fails at level 3 with expression: ****** error in function symVar2
(SEQ (|:=| (|:| |x| (|Variable| | << y >> |)) | << y >> |) (|exit| 1 (|:=| (|:| |t| (|Boolean|)) |true|))) ****** level 3 ****** $x:= y $m:= (Variable y) $f:= ((((|x| #) (|symVar2| #) (|$DomainsInScope| # # #) (% # #) ...)))
>> Apparent user error: NoValueMode is an unknown mode
(b) We can compile x:Variable(y):=y
if we first declare y: Variable(y)
(without assignment, SVT3).
)abbrev package SVT3 SymbolVariableTest3 SymbolVariableTest3(): Spec == Imp where Spec == with symVar3:() -> Boolean Imp == add symVar3()== y: Variable(y) x: Variable(y):=y t:Boolean:= true
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/8532403455899499600-25px007.spad using old system compiler. SVT3 abbreviates package SymbolVariableTest3 ------------------------------------------------------------------------ initializing NRLIB SVT3 for SymbolVariableTest3 compiling into NRLIB SVT3 compiling exported symVar3 : () -> Boolean Time: 0 SEC.
(time taken in buildFunctor: 0)
;;; *** |SymbolVariableTest3| REDEFINED
;;; *** |SymbolVariableTest3| REDEFINED Time: 0 SEC.
Warnings: [1] symVar3: y has no value
Cumulative Statistics for Constructor SymbolVariableTest3 Time: 0 seconds
finalizing NRLIB SVT3 Processing SymbolVariableTest3 for Browser database: --->-->SymbolVariableTest3(constructor): Not documented!!!! --->-->SymbolVariableTest3((symVar3 ((Boolean)))): Not documented!!!! --->-->SymbolVariableTest3(): Missing Description ; compiling file "/var/aw/var/LatexWiki/SVT3.NRLIB/SVT3.lsp" (written 09 OCT 2024 08:13:22 PM):
; wrote /var/aw/var/LatexWiki/SVT3.NRLIB/SVT3.fasl ; compilation finished in 0:00:00.004 ------------------------------------------------------------------------ SymbolVariableTest3 is now explicitly exposed in frame initial SymbolVariableTest3 will be automatically loaded when needed from /var/aw/var/LatexWiki/SVT3.NRLIB/SVT3
Even though y
was never defined, the function symVar3()
still runs. Actually the local variable x
is assigned Nil
.
symVar3()
>> System error: The variable |y| is unbound.
But we cannot x:Variable(y):=y
if we declare y: Symbol
(without assignment, SVT4
).
)abbrev package SVT4 SymbolVariableTest4 SymbolVariableTest4(): Spec == Imp where Spec == with symVar4:() -> Boolean Imp == add symVar4()== y: Symbol x: Variable(y):=y t:Boolean:= true
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/5583142712275742882-25px009.spad using old system compiler. SVT4 abbreviates package SymbolVariableTest4 ------------------------------------------------------------------------ initializing NRLIB SVT4 for SymbolVariableTest4 compiling into NRLIB SVT4 compiling exported symVar4 : () -> Boolean ****** comp fails at level 2 with expression: ****** error in function symVar4
(SEQ (|:| |y| (|Symbol|)) | << | (|:=| (|:| |x| (|Variable| |y|)) |y|) | >> | (|exit| 1 (|:=| (|:| |t| (|Boolean|)) |true|))) ****** level 2 ****** $x:= (:= (: x (Variable y)) y) $m:= NoValueMode $f:= ((((|y| #) (|symVar4| #) (|$DomainsInScope| # # #) (% # #) ...)))
>> Apparent user error: CANNOT ASSIGN: y OF MODE: (Symbol) TO: x OF MODE: (Variable y)
Not even if we assign a value to y
and we specify a coercion afterwards (SVT5
). This is because no such coercion function exists (even if the target is Union("failed", Variable(y))
. So this differs from the interpreter.
)abbrev package SVT5 SymbolVariableTest5 SymbolVariableTest5(): Spec == Imp where Spec == with symVar5:() -> Boolean Imp == add symVar5()== y: Symbol := y x: Variable(y):=y::Variable(y) t:Boolean:= true
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/2956805564468662474-25px010.spad using old system compiler. SVT5 abbreviates package SymbolVariableTest5 ------------------------------------------------------------------------ initializing NRLIB SVT5 for SymbolVariableTest5 compiling into NRLIB SVT5 compiling exported symVar5 : () -> Boolean ****** comp fails at level 3 with expression: ****** error in function symVar5
(SEQ (|:=| (|:| |y| (|Symbol|)) |y|) (|:=| (|:| |x| (|Variable| |y|)) | << | (|::| |y| (|Variable| |y|)) | >> |) (|exit| 1 (|:=| (|:| |t| (|Boolean|)) |true|))) ****** level 3 ****** $x:= (:: y (Variable y)) $m:= $EmptyMode $f:= ((((|x| #) (|y| # #) (|symVar5| #) (|$DomainsInScope| # # #) ...)))
>> Apparent user error: Cannot coerce y of mode (Symbol) to mode (Variable y)
(c) Although we can compile x:Variable(y):=y
after declaring y:Variable(y)
without assigning a value to y
(SVT3
) and in fact run symVar3()
, we cannot compile a line actually using x
(SVT6
).
)abbrev package SVT6 SymbolVariableTest6 SymbolVariableTest6(): Spec == Imp where Spec == with symVar6:() -> Boolean Imp == add symVar6()== y: Variable(y) x: Variable(y):=y t:Boolean:= x = y
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/7214572082810698305-25px011.spad using old system compiler. SVT6 abbreviates package SymbolVariableTest6 ------------------------------------------------------------------------ initializing NRLIB SVT6 for SymbolVariableTest6 compiling into NRLIB SVT6 compiling exported symVar6 : () -> Boolean ****** comp fails at level 1 with expression: ****** error in function symVar6
(|y|) ****** level 1 ****** $x:= y $m:= (Symbol) $f:= ((((|t| #) (|x| # #) (|y| #) (|symVar6| #) ...)))
>> Apparent user error: Cannot coerce y of mode (Variable y) to mode (Symbol)
Not even testing x=x
(SVT7
). Note that the compiler was apparently trying to use equality from Symbol
, not equality from Variable(y)
. This is a bit bizarre. The identfiers x
and y
even after declaration to be of type Variable(y)
may still be of type Symbol
. On the other hand, an inspection of the code generated for SVT3
shows the equality is in fact from Variable(y)
. So, why does the compiler try to convert y
to Symbol
? Why does SVT6
fail to compile? (I would expect it to compile, but give a run-time error.)
)abbrev package SVT7 SymbolVariableTest7 SymbolVariableTest7(): Spec == Imp where Spec == with symVar7:() -> Boolean Imp == add symVar7()== y: Variable(y) x: Variable(y):=y t:Boolean:= x = x
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/4490168181249298181-25px012.spad using old system compiler. SVT7 abbreviates package SymbolVariableTest7 ------------------------------------------------------------------------ initializing NRLIB SVT7 for SymbolVariableTest7 compiling into NRLIB SVT7 compiling exported symVar7 : () -> Boolean ****** comp fails at level 1 with expression: ****** error in function symVar7
(|y|) ****** level 1 ****** $x:= y $m:= (Symbol) $f:= ((((|t| #) (|x| # #) (|y| #) (|symVar7| #) ...)))
>> Apparent user error: Cannot coerce y of mode (Variable y) to mode (Symbol)
(d) But if we stay with the domain Symbol
, we can compile without a problem even if y
is never assigned (SVT8
).
)abbrev package SVT8 SymbolVariableTest8 SymbolVariableTest8(): Spec == Imp where Spec == with symVar8:() -> Boolean Imp == add symVar8()== y:Symbol x:Symbol:= y t:Boolean:= (x=y)
Compiling FriCAS source code from file /var/lib/zope2.10/instance/axiom-wiki/var/LatexWiki/6938772839598774218-25px013.spad using old system compiler. SVT8 abbreviates package SymbolVariableTest8 ------------------------------------------------------------------------ initializing NRLIB SVT8 for SymbolVariableTest8 compiling into NRLIB SVT8 compiling exported symVar8 : () -> Boolean Time: 0 SEC.
(time taken in buildFunctor: 0)
;;; *** |SymbolVariableTest8| REDEFINED
;;; *** |SymbolVariableTest8| REDEFINED Time: 0 SEC.
Warnings: [1] symVar8: y has no value
Cumulative Statistics for Constructor SymbolVariableTest8 Time: 0 seconds
finalizing NRLIB SVT8 Processing SymbolVariableTest8 for Browser database: --->-->SymbolVariableTest8(constructor): Not documented!!!! --->-->SymbolVariableTest8((symVar8 ((Boolean)))): Not documented!!!! --->-->SymbolVariableTest8(): Missing Description ; compiling file "/var/aw/var/LatexWiki/SVT8.NRLIB/SVT8.lsp" (written 09 OCT 2024 08:13:22 PM):
; wrote /var/aw/var/LatexWiki/SVT8.NRLIB/SVT8.fasl ; compilation finished in 0:00:00.004 ------------------------------------------------------------------------ SymbolVariableTest8 is now explicitly exposed in frame initial SymbolVariableTest8 will be automatically loaded when needed from /var/aw/var/LatexWiki/SVT8.NRLIB/SVT8
Computing the next result, which produces the error below in Windows version, is not displayed properly by MathAction because the system error causes Axiom to return an error condition.
symVar8()
Like Variable(y)
, in SVT8
, y
is considered undefined, but unlike SVT1
, SVT8
produces a run time error. Which one is a bug?
>> System error: equal: x is a NULL pointerprotected-symbol-warn called with (NIL)
Thanks for fixing some of the problems on MathAction in IssueTracker #110 and also rebroadcasting the page.
Did you change the editor? The page is now defaulted to HTML+LaTeX and the editor that came up when I hit the edit button is a fancy editor with tool bars. On the other hand, I did not get the "raw" text. When I simply insert a carriage return before the header "Compiler", the preview shows error.
Resetting the format to Structured Text + LaTeX will mess up (line breaks, etc) the preview as well.
William
William, I am sorry for this oversight. I did not intentionally change the editor. I forgot that by default the wiki uses a "fancy editor" called Epoz for the HTML page type. This editor assumes that the content is pure HTML and is supposed to let people who don't know HTML produce nicely formatted pages. Unfortunately the pages that we are editing contain embedded LaTeX commands that seem to completely confuse it. There is a way to change the mode to plain text editing, but I think that on the whole this is more trouble than it is worth. Therefore I have disabled Epoz and you should be able to edit the HTML+LaTeX page in the same way as the StructuredText+LaTeX pages.The reason that I changed the page type to HTML+LaTeX is because I have found that it often produces a better formated page when the page contains compiler output. --------- Bill Page.
Status: open => closedThis is rather a discussion than a bug report. I moved its contents to a new page SymbolsAndVariables